LaPolla Header
Acrylic Roof Coating
Our Promise to You... Quality Every Time.

 

Factory Mutual (FM Approvals)

 

Listing: LaPolla Industries, Inc.

 

Class: 4470 Severe Hail Rating

Substrates:

Concrete, recover (existing BUR), and Steel Deck Roofing

Trade Names:

RCS-5000, Therm-O-Flex, TF-750, TF-1000, TF 1500 HT, FE 348
Application Rates:
.3.0 – 3.5 gallons per square
   
Testing: ASTM E108 Spread of Flame (All products)

Result:

Class A Rating

Slope:

RCS-5000, TF-750 and TF-1000 at 2:12, TF1500HT at 1.5:12
   
Testing:  Simulated hail damage tests (TF-1000, TF-750, TF1500HT)

Result:

Severe Hail rating approval over FE 348
   
Testing: Susceptibility to Leakage test

Result:

No Sign of water leakage observed.
     
Conclusions:
  1. LaPolla’s RCS-5000, Therm-O-Flex, TF-750, TF-1000 and TF1500HT meet the FM standard 4470 Approval requirement for class 1 windstorm when installed as tested.
  2. LaPolla’s RCS-5000, Therm-O-Flex, TF-750, TF-1000 and TF1500HT roof covers meet the severe hail rating.
  3. See report for wind uplift and other configurations.
     

*These results are intended as a guideline and reference.  For actual report copies please refer to the agencies websites or consult with your LaPolla technical representative.  Updates and changes may be made without notice.

   
     
   